Inverter Agnostic Monitoring System for India’s Solar, Wind and BESS Plants

Most SCADA systems lock you into a single inverter brand. EnerCog Synapse doesn’t. It connects to any inverter, any protocol — and starts delivering 1-second sampled data from day one. No proprietary hardware replacements. No renegotiating with vendors. Just plant intelligence that works with what you already have.

The Problem With Brand-Locked Monitoring

Solar EPCs and O&M companies in India manage plants from 10+ inverter brands — Sungrow, ABB, Delta, Growatt, SMA, Fronius, and more. Most monitoring systems force you to choose: buy our inverter ecosystem, or lose half your visibility. For multi-brand portfolios, this means patching together 3-4 dashboards, manual data reconciliation, and missing the early fault signals that cost you generation loss.

The real cost isn’t just operational — it’s in DSM penalties from SLDC and avoidable downtime that compounds across your fleet.

EnerCog Synapse: One Controller. Every Inverter Brand.

Synapse is EnerCog’s edge intelligence controller (iRTU) built for multi-inverter, multi-asset renewable energy plants. It speaks RS485/Modbus RTU natively — with auto-configuration that identifies connected devices and maps registers without manual setup. Where SCADA vendors charge days of commissioning time, Synapse cuts onboarding by 70%.

Technical Specifications

Protocol support:

RS485 / Modbus RTU, Modbus TCP, IEC 104, DNP3

Auto-configuration:

Automatic device discovery and register mapping on RS485 bus — no manual configuration required

Sampling rate:

1-second data acquisition — captures transient faults missed by 5-minute SCADA polling

Edge AI:

On-device anomaly detection and arc fault identification — alerts before faults become failures

Inverter compatibility:

Works with any Modbus-speaking inverter brand — Sungrow, ABB, Delta, Growatt, SMA, Fronius, Huawei and more

BESS integration:

Native support for battery storage systems — monitors SOC, degradation indicators, and charge/discharge cycles

Wind asset support:

Connects to wind turbine controllers via standard industrial protocols.

Connectivity:

LTE / Wi-Fi / Ethernet with local edge buffering for offline resilience

Certifications:

CE, industrial-grade enclosure for outdoor installation

Why EPCs and O&M Teams Choose Synapse

70% Faster Commissioning

RS485 auto-configuration replaces days of manual register mapping. Synapse connects to your inverter bus and identifies all devices automatically.

96%+ Forecast Accuracy

1-second edge data feeds EnerCog Cortex cloud AI for generation forecasting — delivering accuracy that meets SLDC scheduling requirements.

Arc Fault
Detection

On-device edge AI detects arc fault signatures in real time — before they trigger inverter shutdowns or become fire hazards on your plant.

Built for Indian Regulatory Compliance

Synapse is engineered to meet India-specific constraints that generic SCADA ignores. IEC 104 protocol support ensures compatibility with SLDC SCADA systems for grid-connected plants under CERC/SERC scheduling mandates. For PM-KUSUM Component A projects, Synapse provides the real-time monitoring data required for MNRE portal compliance — eliminating manual submission workflows.

Frequently Asked Questions

If the inverter communicates over RS485 with a standard Modbus register map, Synapse can connect to it. For proprietary register maps, EnerCog provides a configuration service to add support within days. Over 95% of inverters sold in India use standard Modbus — and Synapse auto-configures all of them.

Synapse is cost-effective from 100 kW rooftop commercial plants up to 100 MW+ utility-scale projects. A single controller handles up to 32 RS485 devices on one bus, with multi-bus expansion for larger plants.

Standard SCADA polls inverters every 5 minutes. Most transient faults — arc faults, string disconnections, clipping events — resolve within 30-60 seconds and are invisible at 5-minute resolution. Synapse’s 1-second edge sampling captures these events and flags them in real time, reducing energy loss from undetected faults by up to 2-3% annually.

Synapse is designed as a cost-effective alternative to full SCADA for most Indian solar and wind projects. For plants that already have SCADA investments, Synapse can operate as an edge data concentrator feeding higher-accuracy data into existing systems without full replacement.


EnerCog also offers end-to-end AI energy management solutions for EPCs, IPPs, and industrial buyers — including SLDC-compliant generation forecasting and PM-KUSUM compliance monitoring.